How to use our starter solenoid lookup:

Filter by part number, voltage or terminal count, then open the matching record. Compare the recorded circuit, mounting and duty ratings before checking the current manufacturer application.

Browse specifications

These records are included in the page; no Load button or account is needed.

72 records. Open a part to see its recorded specifications.

  • 1M1369 — 12 Volt, 2 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    35 amps closed
    Notes
    Not listed
  • 1M1054 — 12 Volt, 3 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, Curved Bracket
    Housing
    Plastic or Steel/Zinc Plt.
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1344 — 12 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1345 — 12 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    9/32x25/64, 2 7/64 on centers
    Housing
    Phenolic
    Circuit type
    Grounded base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1346 — 12 Volt, 3 terminals
    Recorded application
    Marine Rated- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1347 — 12 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 1/8 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1352 — 12 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1353 — 12 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    9/32x1/2 slots, 2 13/64 on center
    Housing
    Phenolic
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1354 — 12 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1355 — 12 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1383 — 12 Volt, 3 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 12 volts
    Notes
    Not listed
  • 1M1384 — 12 Volt, 3 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 12 volts
    Notes
    Not listed
  • 1M1385 — 12 Volt, 3 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 1/8 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 12 volts
    Notes
    Not listed
  • 1M1392 — 12 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1401 — 12 Volt, 3 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Not listed
    Circuit type
    Grounded base
    Intermittent rating
    250 amps intermittent
    Continuous rating
    100 amps @ 12 volts
    Notes
    Not listed
  • 1R2079 — 12 Volt, 3 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    100 amps @ 12 volts
    Notes
    Not listed
  • 1M1022 — 12 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plastic
    Circuit type
    Not listed
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1023 — 12 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1025 — 12 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1026 — 12 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plastic
    Circuit type
    Not listed
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1029 — 12 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Plastic
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1030 — 12 Volt, 4 terminals
    Recorded application
    Automotive Universal
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1030A — 12 Volt, 4 terminals
    Recorded application
    Automotive Universal
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1088 — 12 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    With diode protection
    Mounting bracket
    Not listed
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1090 — 12 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    With diode protection
    Mounting bracket
    Not listed
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1090A — 12 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1091 — 12 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    With diode protection
    Mounting bracket
    Not listed
    Housing
    Not listed
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1349 — 12 Volt, 4 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    With resistor shorting circuit- Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1350 — 12 Volt, 4 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    With resistor shorting circuit- Copper contacts
    Mounting bracket
    9/32x1/2 slots, 2 13/64 on center
    Housing
    Phenolic
    Circuit type
    Grounded base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1356 — 12 Volt, 4 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1357 — 12 Volt, 4 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plasticized Steel Housing
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1358 — 12 Volt, 4 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1359 — 12 Volt, 4 terminals
    Recorded application
    Marine Rated- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1360 — 12 Volt, 4 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    9/32x25/64, 2 7/64 on centers
    Housing
    Phenolic
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1370 — 12 Volt, 4 terminals
    Recorded application
    Continuous Duty Latching
    Electrical data
    Used as battery disconnect or battery isolation
    Mounting bracket
    9/32x25/64, 2 1/8 on centers
    Housing
    Not listed
    Circuit type
    Not listed
    Intermittent rating
    Not listed
    Continuous rating
    110 amp carry only
    Notes
    Not listed
  • 1M1373 — 12 Volt, 4 terminals
    Recorded application
    Marine Rated-Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps
    Notes
    Not listed
  • 1M1374 — 12 Volt, 4 terminals
    Recorded application
    Marine Rated-Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plasticized Steel Housing
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 30 minutes off
    Continuous rating
    65 amps @ 12 volts
    Notes
    Not listed
  • 1M1376 — 12 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Silver contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    200 amps @ 12 volts
    Notes
    Not listed
  • 1M1386 — 12 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 12 volts
    Notes
    Not listed
  • 1M1387 — 12 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plasticized Steel Housing
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 12 volts
    Notes
    Not listed
  • 1M1398 — 12 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Not listed
    Circuit type
    Insulated base
    Intermittent rating
    250 amps intermittent
    Continuous rating
    100 amps @ 12 volts
    Notes
    Not listed
  • 1M1468 — 12 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Steel
    Circuit type
    Not listed
    Intermittent rating
    160 amps intermittent
    Continuous rating
    80 amps continuous
    Notes
    For snow plow use
  • 1M1470 — 12 Volt, 4 terminals
    Recorded application
    Marine Application
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1573 — 12 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Not listed
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    80 amps continuous
    Notes
    Not listed
  • 1M1367 — 12 Volt, 5 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 1/8 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    SPDT for forward & reverse systems. 35 amp closed 85 amp open
    Notes
    Not listed
  • 1M1400 — 12 Volt, 5 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    Slots
    Housing
    steel
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    100 amps (unverified)
    Notes
    Garden tractors & Golf carts/forklits
  • 1M1366 — 12 Volt, 6 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 1/8 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    SPDT for forward & reverse systems. 35 amp closed 85 amp open
    Notes
    Not listed
  • 1M1368 — 12 Volt, 6 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plasticized Steel Housing
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    SPDT for forward & reverse systems. 35 amp closed 85 amp open
    Notes
    Not listed
  • 1M1343 — 24 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    120 amp make, 65 amp break, 10 seconds on 30 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1381 — 24 Volt, 3 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 24 volts
    Notes
    Not listed
  • 1M1382 — 24 Volt, 3 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 24 volts
    Notes
    Not listed
  • 1M1342 — 24 Volt, 4 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    120 amp make, 65 amp break, 10 seconds on 30 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1375 — 24 Volt, 4 terminals
    Recorded application
    Marine Rated-Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plasticized Steel Housing
    Circuit type
    Insulated base
    Intermittent rating
    120 amp make, 65 amp break, 10 seconds on 30 minutes off
    Continuous rating
    65 amps @ 24 volts
    Notes
    Not listed
  • 1M1377 — 24 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Silver contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    200 amps @ 24 volts- Carry only, not break
    Notes
    Not listed
  • 1M1380 — 24 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 24 volts
    Notes
    Not listed
  • 1M1365 — 24 Volt, 6 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 1/8 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    SPDT for forward & reverse systems. 35 amp closed 85 amp open
    Notes
    Not listed
  • 1M1371 — 36 Volt, 4 terminals
    Recorded application
    Marine Rated-Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    9/32x11/16, 2 7/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    120 amp make, 65 amp break, 10 seconds on 30 minutes off
    Continuous rating
    65 amps @36 volts
    Notes
    Not listed
  • 1M1372 — 36 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Plasticized Steel Housing
    Circuit type
    Insulated base
    Intermittent rating
    120 amp make, 65 amp break, 10 seconds on 30 minutes off
    Continuous rating
    65 amps @36 volts
    Notes
    Not listed
  • 1M1378 — 36 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    9/32x11/16, 2 7/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 36 volts
    Notes
    Not listed
  • 1M1379 — 36 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Plasticized Steel Housing
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 36 volts
    Notes
    Not listed
  • 5S4216 — 36 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    40 Amps @ 36 volts
    Notes
    Not listed
  • 1M1364 — 36 Volt, 6 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, 2 1/8 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    SPDT for forward & reverse systems. 35 amp closed 85 amp open
    Notes
    Not listed
  • 1M1053 — 6 Volt, 3 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    5/16x19/32 slots, Curved Bracket
    Housing
    Steel/Zinc Plt.
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1095 — 6 Volt, 3 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Plastic
    Circuit type
    Insulated base
    Intermittent rating
    Positve Ground/S wire switched to ground
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1096 — 6 Volt, 3 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Plastic
    Circuit type
    Grounded base
    Intermittent rating
    Negative Ground/S wire switched to positve
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1330 — 6 Volt, 3 terminals
    Recorded application
    Agricultural
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Not listed
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1361 — 6 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 1/8 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1362 — 6 Volt, 3 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 1/8 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1388 — 6 Volt, 3 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Grounded base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 6 volts
    Notes
    Not listed
  • 1M1363 — 6 Volt, 4 terminals
    Recorded application
    Industrial- Intermittent Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 1/8 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    750 amp make, 100 amp break, 10 seconds on 20 minutes off
    Continuous rating
    Not listed
    Notes
    Not listed
  • 1M1389 — 6 Volt, 4 terminals
    Recorded application
    Continuous Duty Cycle
    Electrical data
    Copper contacts
    Mounting bracket
    5/16x19/32 slots, 2 13/64 on centers
    Housing
    Steel
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    85 amps @ 6 volts
    Notes
    Not listed
  • 1M1516 — 6 Volt, 4 terminals
    Recorded application
    Automotive Application
    Electrical data
    Not listed
    Mounting bracket
    Not listed
    Housing
    Not listed
    Circuit type
    Insulated base
    Intermittent rating
    Not listed
    Continuous rating
    Not listed
    Notes
    Not listed

Source and limits

Source: GoTech’s existing starter-solenoid database, retrieved November 2, 2026. The original reference page was published August 3, 2022. Retrieval checks the records we displayed; the underlying dataset revision and current manufacturer coverage remain unverified.

“Not listed” means the source field is blank or says “No Data”; it does not mean zero or not applicable. Preserve the stated units and conditions. Confirm current part specifications, wiring and fitment with manufacturer information before testing, installation or substitution.

Article provenance

Source mdx-da102589738c4f1d2916

SHA-256 ca5ecfc05d3ba12c5a14fe086e696f8202ebcca37b961e9d5d89a2ee00b39b0f

Continue with the job

Honda Accord starter-grinding case: check the mounting and gears

Browse all reference tools · Find a diagnostic guide