What do P0597 and P0598 mean?
- P0597
- Thermostat heater control circuit / open
- P0598
- Thermostat heater control circuit low
The thermostat has an electric heater that lets the engine computer influence when it opens. These are electrical circuit codes; neither code alone identifies the failed part.
Does this cover my Cruze, Sonic or Aveo?
The video identifies a 2014 Chevrolet Cruze; the original written guide identifies the 1.8L application. It also names Sonic and Aveo 1.8L, but does not establish every model year or part number.
The video description mentions 1.4L too. That does not make the housing, access, wiring or specifications interchangeable. Confirm your engine, connector and service procedure before using the replacement steps.
What should I save before testing?
Record all codes, their current/pending/history status and any available freeze frame before clearing them. Note temperature warnings, coolant loss and recent work. Inspect the connector and nearby wiring for damage before reaching for a part.
A heater-circuit code is not proof that the thermostat is mechanically stuck open. Diagnose a warm-up or overheating concern on its own evidence.
Hot engine or coolant loss? Deal with that first. Do not open a hot cooling system. Use your vehicle's warning instructions; this code alone cannot tell you it is safe to keep driving.
Thermostat location and electrical tests
Start at the two-wire connection shown below. Test the disconnected thermostat first; the harness and computer control are a separate check.
2014 Cruze 1.8L thermostat connector location
The arrow identifies the two-wire heater connection on the thermostat housing in GoTech’s case vehicle. Use this image to orient yourself before unplugging it; it is not a location guide for the 1.4L.
Enlarge the thermostat connector locationHow to test the thermostat heater with a multimeter
- Let it cool and inspect the connection. With the ignition off, unplug the two-wire thermostat connector. Look for damaged wires, poor terminals or contamination. Don't force oversized probes into the terminals.
- Check your meter setup. Select resistance and touch the leads together to check for a low reading. Use resistance mode only on the disconnected, unpowered component. Watch the meter setup 1:12
- Measure across the thermostat's two terminals. Record the reading, units and test conditions. In this case, GoTech compares the old heater with known-good units and later checks the replacement.
This is the range the presenter reports from good units he has tested. He specifically says it was not a resistance specification in the GM service information he consulted. Treat it as case evidence, not a universal pass/fail limit.
Hear where the range comes from 0:34
Enlarge illustration 2Can the computer command it—and let it go?
In the video, the presenter connects a test light across the harness-side connector and uses a bidirectional scan tool to command the heater. This checks the circuit under the demonstrated test load. Watch the control test 2:20
Before making that connection on your vehicle, use its wiring diagram and specified test equipment/load. The video does not establish that any test light is suitable for every computer-controlled circuit. If you cannot confirm the setup, have this check performed with the correct equipment.
Enlarge illustration 3- Notice the initial lamp response. The lamp is already lit in the case. The presenter does not stop there—he checks whether he can change the command and release it.
- Compare command with response. As the command increases, the video describes more on-time and a brighter lamp. That is not a claim that pulse frequency must increase. Compare the commanded response 3:12
- Release control. The lamp goes out in the demonstration. Together, those observations support the circuit's ability to operate that test load at that time. They do not rule out every intermittent fault.
I don't have a bidirectional scan tool. Can I still decide?
You can inspect the connector and record a heater reading with the correct setup. But a brief lamp response at key-on is not the same as commanding the output up and then releasing it.
If control remains untested, keep that gap in the diagnosis. A failed command test also does not automatically mean a bad computer: the supply, connections, control wiring and test setup still need to be separated using the vehicle's procedure.
Choose the next step from your test results
Heater fault supported; control responds
That's the path shown in the Cruze. The old heater is described as nearly open, the commanded lamp response changes and releases, and the new thermostat measures about 15Ω. Those findings support the thermostat replacement in this case. See the replacement comparison 4:30
Check the part and prepare for replacement →Control doesn't respond as expected
Stop before condemning the computer or assuming a thermostat will solve it. Recheck the setup, then follow the wiring test to distinguish supply, terminal, harness and driver faults. Save the command and response you observed.
Return to the control-test boundary →The reading looks plausible, or the fault isn't present
A plausible heater reading does not clear the whole system. Compare the original code conditions, connector condition and the applicable circuit tests. If you cannot reproduce it, call the result inconclusive rather than selecting a part.
Return to the original evidence →Watch the complete GoTech diagnosis and repair
10:56 · The chapters throughout this guide play here. Use “Back to where you were” to return to your step.

Video loads only when you choose to play.
Thermostat replacement: parts, removal and refill
The steps below follow the demonstrated Cruze repair. Match your housing and service information before taking it apart.
Parts & tools: what you need and why
Parts and supplies
- The correct thermostat/heater assembly and seal. Confirm VIN/engine fitment, connector and housing. The video does not identify a verified replacement part number, so we are not assigning one from appearance.
- The specified coolant, a drain pan and a refill plan. Have the correct quantity and fill/bleed procedure for your vehicle before draining it. See the coolant reference below.
- Any separately confirmed leaking part. Inspect the nearby coolant tube rather than automatically adding it to the order.
As an Amazon Associate, GoTech earns from qualifying purchases through the tool links below. These are tools to match to the job, not proof of part fitment.
- For the diagnosis
- Multimeter and terminal leads; a bidirectional scan tool and the circuit's specified test load for control checks.
- For removal
- Ratchet, extension and a socket that fits your housing fasteners; hose-clamp pliers and a drain pan.
- For installation
- Inch-pound torque wrench, correct seal and the equipment for your approved coolant-fill method.
The original article lists an E10 external Torx socket. Confirm the actual fastener profile and size; do not force a socket because a similar engine used it.
1. Cool, drain and remove the housing
Wait for the cooling system and cap to cool. An hour on a clock is not proof it is safe to open. Release any remaining pressure using the vehicle's prescribed procedure. Follow the removal 4:42
- Disconnect the thermostat connector and secure nearby wiring clear of the coolant and work area.
- Place a drain pan below the job. Compress the hose clamp with the proper tool and move it back along the hose. Keep your fingers clear of the spring clamp.
Enlarge illustration 4- Ease the hose off without damaging it, direct the coolant into the pan and let it drain.
- Remove the four housing bolts with the correct-fitting socket. Ease the thermostat assembly away from its sealing surface.
Enlarge illustration 52. Seat the seal and install the replacement
Inspect the sealing surface 7:00 · Follow installation 7:39
- Clean and inspect the mating surface using the approved method. Avoid damaging the surface or introducing debris.
- Check that the replacement's seal is correctly installed, then position the assembly without forcing it.
Enlarge illustration 6- Start all four bolts by hand. The video gives 71 in-lb for its housing bolts—not ft-lb. Verify the specification for your exact assembly before tightening.
- Refit the hose and clamp in their original positions. Reconnect the thermostat and restore any wiring or components moved for access.
3. Refill correctly—don't leave the job at “add coolant”
The video discusses a spill-free funnel and demonstrates a vacuum-fill tool. Use the fill/bleed method specified for your vehicle and the tool's instructions. A topped-up reservoir alone does not establish that the system is full and free of trapped air. Watch the refill discussion 9:21
Enlarge illustration 72014 Cruze reference: Chevrolet specifies a 50/50 mixture of clean, drinkable water and DEX-COOL coolant. Its manual explains the cold-system pressure-cap procedure, filling and the later cold-level recheck. Read Vehicle Care 10-21–10-23 alongside the service procedure for a drained system.
Do not open a hot cap or continue a run check with a leak or overheating warning. Collect spilled coolant and arrange appropriate disposal.
Now check both parts of the repair: the circuit and the cooling system →
Check the repair before calling it fixed
Putting the housing on is one part of the job. Before calling it finished, return to what you found and check the work you disturbed.
- Check the installation. Confirm the connector, hose, clamp and seal are seated, nearby wiring is restored, and no coolant leak remains.
- Finish the cooling-system checks. Complete the specified refill and air-removal procedure, watch for leaks or temperature warnings during the prescribed run check, and recheck the level once fully cold. Use the 2014 Cruze manual's cold-level guidance for that application.
- Return to the electrical fault. Use the vehicle's diagnostic repair-verification procedure to recheck the original heater/control concern. Compare the result with what you recorded before repair.
- Read codes and test status again. Save the original evidence before any reset. Clearing the light is not a completed passing test; use the applicable conditions to see whether the fault returns.
The video shows replacement, filling and a plan to clear codes. It does not document a completed drive-cycle or long-term monitor pass. The checklist above is a recheck plan, not a claim those results were shown.
P0597 or P0598 came back after replacement
Save the exact code and when it returned. With the engine cool and ignition off, inspect the connector and wiring disturbed during the job and confirm the installed part matches the vehicle. Then use the heater and control checks to separate a component concern from a circuit concern. A new thermostat does not prove the wiring or control is working.
Compare the test outcomes →The code is gone, but coolant is leaking or temperature is wrong
The electrical concern and cooling-system behavior are separate checks. Stop the run test for a leak or overheating warning and follow the cooling-system procedure. An unlit warning lamp does not clear a coolant fault.
Review the refill and cooling-system checks →I can't complete the verification yet
Keep it marked as not yet verified. Record the repair, available readings and the outstanding test conditions so the next check starts with evidence rather than another parts guess.
Sources & coverage
Original GoTech guide published January 26, 2023 · Repair guidance refined October 19, 2026 · Search and reading refinement October 31, 2026.
Chevy Cruze Heated Thermostat Testing and Repair supplies the demonstrated diagnosis and repair. The written guide adds navigation, comparisons and an explicit recheck plan; it does not turn the case into a procedure for every GM engine.
2014 Chevrolet Cruze Owner Manual, Vehicle Care 10-19–10-23, supports the coolant and cold-level references. Use current vehicle-specific service information for wiring, approved test loads, specifications and repair verification.
What still needs application-specific confirmation?
Exact replacement part, model-year fitment, fastener specification, circuit test load and monitor conditions. The observed 13–15Ω comparison is not a universal GM specification. No independent technician review or long-term repair outcome is claimed.
Article provenance
Source mdx-3fe21a36276ed8fc7ab7
SHA-256 88f136dc0831bfd187c135c25fcd2112d47abd06f3f2d4642fe069728b32fdce